Swapping a standard strike plate for an electric strike turns a static commercial door into part of your access control system — but only if it's installed correctly for your specific door, lockset, and power requirements. Get the fail-safe/fail-secure mode wrong, mismatch the strike to your hardware, or miscount the amp draw on your power supply, and you end up with a door that won't latch, won't unlock, or fails inspection.

This guide walks through how electric strike lock installation for commercial doors actually works — from picking the right strike to wiring it into your access control panel — so you know what a proper install involves whether you're planning to hire it out or evaluate a quote.

What Is an Electric Strike Lock?

An electric strike (sometimes called an electric door strike) replaces the fixed metal keeper that a latch bolt sits in. Instead of staying rigid, the keeper's "lip" or "jaw" pivots open when the strike is energized, letting the door swing free without anyone turning a key. It works alongside your existing lockset — the strike doesn't replace the lock itself, it replaces the plate the lock's latch engages.

That's what makes electric strikes popular for commercial buildings: businesses can keep their existing cylindrical lock, mortise lockset, or exit device on the door and add remote-release capability — triggered by a keypad, card reader, intercom buzzer, or push-button release at a front desk — without re-keying everything.

Fail-Safe vs. Fail-Secure: Get This Decision Right First

This is the single most important decision in the entire installation, and it has to happen before you order parts.

  • Fail-secure (power-to-unlock): The strike stays locked when power is lost and only unlocks when energized. This is the default choice for most exterior commercial doors, and it's typically required on doors that are part of a fire-rated UL assembly, since the door needs to stay secured if the building loses power.
  • Fail-safe (power-to-lock): The strike stays unlocked when power is lost and only locks when energized. This mode is common on doors along a fire egress path, where code may require the door to release automatically during a power outage so people aren't trapped.

Which mode you need depends on the door's role in your building's life-safety plan, not personal preference. If the door is on a fire exit route or part of a rated assembly, check with your local fire marshal or building code before buying hardware — this is one of those details worth confirming locally rather than guessing. For a deeper look at why this distinction matters across an entire building, our page on why access control is important covers how door-by-door power logic fits into a broader security plan.

Before You Start: Compatibility and Tools

Electric strikes aren't universal. A strike built for a mortise lockset won't work with a rim exit device, and a strike sized for a hollow metal frame won't drop cleanly into an aluminum storefront jamb. Before buying anything, confirm:

  • Lockset type — cylindrical deadlatch, mortise lock, or exit device with a rim latch
  • Frame material — hollow metal, aluminum storefront, or wood
  • Door handing — left-hand or right-hand swing
  • Voltage and current draw of your access control panel — the strike has to match what your power supply and controller can deliver
  • Latch projection and backset — needs to line up with the strike's "keeper" throat depth

Commercial-grade strikes from manufacturers like HES are sold with manufacturer-specific installation templates (the HES 8000-series, for example, ships with its own template and instruction sheet). Always follow the manual and template that comes with the specific strike you bought rather than a generic diagram — strike dimensions, mounting screw patterns, and faceplate cutouts vary by model and revision.

Tools typically needed: a drill with metal and wood bits as appropriate, a jig or template (from the manufacturer), a file or Dremel for frame cleanup, wire strippers, a low-voltage multimeter, and screwdrivers matching the strike's mounting hardware.

Before You Start: Compatibility and Tools

How to Install an Electric Strike Lock: Step by Step

Step 1: Remove the Existing Strike Plate

Unscrew and remove the standard strike plate from the door frame. Note how the latch currently seats — this tells you where the electric strike's keeper needs to land.

Step 2: Position the Manufacturer's Template

Tape the strike's installation template to the frame, aligned with the existing latch opening. This step matters more than it sounds — an electric strike's keeper has to catch the latch at the exact same point the old strike did, or the door won't close properly.

Step 3: Cut or Modify the Frame Opening

On a wood door frame: This is usually the more forgiving install. You can typically enlarge the existing mortise with a chisel or router guide, following the template's outline.

On a metal door frame: Installing an electric strike in a metal frame generally requires more precision — hollow metal frames often need the opening cut with a specific jig, and some installs call for a metal cutting attachment or professional frame prep to avoid weakening the jamb. Many commercial strikes are designed as direct ANSI strike replacements specifically to minimize how much metal has to be cut.

Step 4: Mount the Strike Body

Set the strike into the prepared opening and secure it with the mounting screws specified in the manual. Confirm the keeper moves freely and the faceplate sits flush with the frame — a strike that protrudes or sits recessed will cause latching problems later.

Step 5: Wire the Strike

This is where the electric strike lock wiring diagram comes in, and every manufacturer's diagram looks a little different, but the basic circuit is the same in concept:

  • Low-voltage wire runs from the strike, through the frame (often via a door loop or electric hinge if the wire needs to cross from frame to door, though most strikes mount in the frame and don't need this), back to a power source.
  • The power source is usually a dedicated power supply or the access control panel's auxiliary output — not a standard building outlet.
  • A request-to-exit (REX) device or the access control reader provides the trigger signal that energizes (or de-energizes) the strike.
  • Many installs also include a door position switch or contact so the access control system knows when the door is open versus just unlocked.

Match wire gauge and voltage to the strike's spec sheet exactly — undersized wire or the wrong voltage is a common reason strikes buzz, chatter, or fail to fully retract.

Step 5: Wire the Strike

Step 6: Connect to the Access Control System

Tie the strike's control wires into your reader, keypad, or intercom release relay. If you're integrating with a broader building system — multiple doors, card readers, time-based schedules — this is the point where the strike becomes part of your access control deployment. See our door access control page for how electric strikes typically fit alongside readers, controllers, and credentials in a full system.

Step 7: Test Before Closing Everything Up

With power connected, test:

  • The strike releases on command (keypad, card, button) and relocks correctly
  • The door latches fully when closed, without needing extra force
  • Fail-safe/fail-secure behavior matches what the door requires — pull power and confirm the door does what it's supposed to do when de-energized
  • No buzzing, chattering, or excess heat at the strike body

Only after testing should you install the final frame trim or cover plates.

Double Door Electric Strike Installation: What's Different

Pairs of commercial doors add a wrinkle: usually one door is the "active" leaf (the one people actually push/pull) and the other is the "inactive" leaf, often secured with a flush bolt or astragal. For double door electric strike installation:

  • The electric strike almost always goes on the active leaf, where the latch or exit device actually engages
  • The inactive leaf typically needs its own fixed or automatic flush bolts, since the strike only controls one side
  • Alignment between the two doors matters more here — any gap or misalignment at the meeting edge can prevent the active leaf's latch from seating in the strike correctly
  • If both leaves need independent remote release (less common), each door needs its own strike and its own wiring run, which roughly doubles the labor and conduit work

Double Door Electric Strike Installation: What's Different

DIY Electric Strike Installation vs. Hiring a Pro

A confident DIYer with the right tools can install an electric strike on a straightforward wood-frame door with basic low-voltage wiring. Where DIY installs tend to go wrong:

  • Cutting a metal frame without the right jig, which can crack or warp the frame
  • Choosing the wrong fail-safe/fail-secure mode for a fire-rated or egress door
  • Miswiring power polarity or undersizing wire gauge, causing intermittent failures
  • Skipping local electrical code requirements for low-voltage runs in a commercial building
  • Not accounting for how the strike interacts with an existing access control panel's power budget

None of this means it can't be done — it means the margin for error on a commercial door is higher than on a home project, especially where fire code and egress requirements apply. If the door is tied into a building-wide access control system, part of a rated assembly, or you're not confident reading a wiring diagram, it's worth having an experienced commercial locksmith handle the install or at least review your plan before you cut into the frame. Our team's commercial locksmith services page outlines what's typically included in professional electric strike and access control installs for Atlanta-area businesses.

Electric Strike Installation Checklist

Use this as a working checklist before and during installation:

Step What to Confirm Done?
1 Strike type matches lockset (cylindrical / mortise / exit device) ☐
2 Fail-safe or fail-secure mode confirmed against fire/egress code ☐
3 Door handing and frame material (metal, wood, aluminum) identified ☐
4 Manufacturer template and manual on hand (e.g., HES 8000-series template) ☐
5 Power supply voltage/current matches strike spec sheet ☐
6 Wire gauge matches manufacturer wiring diagram ☐
7 Frame opening cut/prepped per template, not freehand ☐
8 Strike mounted flush, keeper moves freely ☐
9 Wiring run tested with multimeter before final connection ☐
10 Door latches properly with power on and off ☐
11 Fail-safe/fail-secure behavior verified with power cut ☐
12 For double doors: inactive leaf secured independently ☐

Common Mistakes That Lead to Call-Backs

  • Buying a strike based on door size alone instead of matching it to the exact lockset
  • Ignoring the manufacturer's template and eyeballing the frame cut
  • Installing fail-safe on a door that code requires to be fail-secure (or vice versa)
  • Running control wire alongside AC power lines, causing electrical interference
  • Forgetting to weatherproof or seal exterior strike installations against moisture

When to Call a Commercial Locksmith

If your electric strike install involves a fire-rated door, a double-door entrance, integration with an existing access control panel, or a metal frame that needs precision cutting, it's generally worth bringing in a commercial locksmith before — not after — you start drilling. A short consultation can confirm the right strike model, the correct fail-safe/fail-secure mode for your door's code classification, and whether your current power supply can handle the added load.

Final Thoughts

Electric strike lock installation for commercial doors is a manageable project when the hardware matches the door and the wiring follows the manufacturer's spec — but small mismatches in mode, voltage, or frame prep cause outsized problems later. Whether you're installing a single strike on a back office door or wiring a full double-door entrance into a building access system, take the time to confirm compatibility and code requirements before you cut.

If you'd rather have it done right the first time, Crown Locksmith works with commercial properties throughout Atlanta, Brookhaven, Chamblee, Tucker, Norcross, Dunwoody, Smyrna, Decatur, Stone Mountain, Stockbridge, and Jonesboro — reach out to talk through your door, your access control setup, and what installation looks like for your specific building.